- IP65 protection level
- Drive various motors
- Isolated air duct
- Widely used in aquaculture farm, water treatment, fan, etc.
We uphold the business philosophy of customer-centricity, survival through quality, and pragmatic innovation.
IP65 Y980 Series is a high-performance and multipurpose VFD. The IP65 protection rating provides the best protection experience for most hash outdoor applications.
Y980 Series full range of independent air duct design, which improves product reliability and performance.
Y980 Series Drives have excellent drive and control performance for using of sensorless vector control technology, and improve usability and reliability for the enriched hardware configurations and software functions, meeting different industrial applications.
Item | Specifications | |
Basic Functions | Maximum Frequency | Vector Control:0~500.0Hz V/F Control:0~500.0Hz |
Carrier Frequency | 0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics. | |
Input Frequency Resolution | Digital Setting: 0.1Hz Analog Setting: 0.01V corresponding maximum frequency ×0.1% | |
Control Mode | Open Loop Vector Control(SVC); V/F Control | |
Startup Torque | G Type:0.5Hz/150%(SVC); P Type:0.5Hz/100% | |
Basic Functions | Speed Range and Precision | 1:100(SVC);±0.5%(SVC) |
Overload Capability | G Type:150% rated current 60s ;180% rated current 3s
| |
Torque Boost | 0.1%~30.0% | |
V/F Curve | Line Type、Square Type | |
Acc. / dec Curve | Straight line or S curve acceleration and deceleration mode Acceleration and deceleration time range between 0.0 to 500.0s. | |
DC Brake | DC Brake Frequency:0.00Hz to maximum frequency. Brake time: 0.0s to 36.0s | |
Multi-speed Running | It can realize at maximum of 8 segments speed running via the control terminal. | |
Built-in PID | It is easy to realize process-controlled closed loop control system. | |
Over-voltage/current Stall Control | It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process. | |
Motor Over-temperature Protection | Acceptable motor temperature sensor input (PT100, PT1000) | |
Timing Control | Timing control function:set time range 0.0~6500.0Min | |
Bus Support | Support Site Bus:Modbus | |
Protection Function | It can implement power-on motor short-circuit detection, output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection, which can be turned on or shielded as required. | |
Running | Running Command Source | Operation panel reference, control terminal reference, and communication reference |
Target Frequency Source | Digital reference, analog signal reference, multi-segment speed reference, PI control reference, and communication reference | |
Control Signal Input Terminal | 2 digital input; 1 analog input ,support 0~10V、4~20mA、0~20mA signal | |
Control Signal Output Terminal | 2 relay output 1 analog output ,support 0~10V、4~20mA、0~20mAsignal | |
Environment | Using Place | Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | 0~4000m;Derating use when more than 1000m (decrease by 1% per 100 meters) | |
Ambient Temperature | -10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9m/s (0.6g) | |
Storge Temperature | -20℃~+60℃ | |
Power Distribution System | TN, TT |