We uphold the business philosophy of customer-centricity, survival through quality, and pragmatic innovation.

img

Y980 Series High-Ingress Protection Drives

IP65 Y980 Series is a high-performance and multipurpose VFD. The IP65 protection rating provides the best protection experience for most hash outdoor applications.

Y980 Series full range of independent air duct design, which improves product reliability and performance.

Y980 Series Drives have excellent drive and control performance for using of sensorless vector control technology, and improve usability and reliability for the enriched hardware configurations and software functions, meeting different industrial applications. 



Product Information

  • Voltage: single/three-phase 220V/380V
  • Power Range: 2.2KW~15KW
  • Maximum Frequency: 0-500Hz
  • 980 Series VFD Manual
  • IP65 protection level
  • Drive various motors
  • Isolated air duct
  • Widely used in aquaculture farm, water treatment, fan, etc.

Specification

Item

Specifications

Basic Functions

Maximum Frequency

Vector Control0~500.0Hz      V/F Control0~500.0Hz

Carrier Frequency

0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics.

Input Frequency Resolution

Digital Setting 0.1Hz

Analog Setting 0.01V corresponding maximum frequency ×0.1%

Control Mode

Open Loop Vector Control(SVC) V/F Control

Startup Torque

G Type0.5Hz/150%(SVC)  P Type0.5Hz/100%

Basic Functions

Speed Range and Precision

1100(SVC)±0.5%(SVC)

Overload Capability

G Type150% rated current 60s 180% rated current 3s

 

Torque Boost

0.1%~30.0%

V/F Curve

Line TypeSquare Type

Acc. / dec Curve

Straight line or S curve acceleration and deceleration mode

Acceleration and deceleration time range between 0.0 to 500.0s.

DC Brake

DC Brake Frequency0.00Hz to maximum frequency. Brake time 0.0s to 36.0s

Multi-speed Running

It can realize at maximum of 8 segments speed running via the control terminal.

Built-in PID

It is easy to realize process-controlled closed loop control system.

Over-voltage/current Stall Control

It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process.

Motor Over-temperature Protection

Acceptable motor temperature sensor input (PT100, PT1000)

Timing Control

Timing control functionset time range 0.0~6500.0Min

Bus Support

Support Site BusModbus

Protection Function

It can implement power-on motor short-circuit detection, output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection, which can be turned on or shielded as required.

Running

Running Command Source

Operation panel reference, control terminal reference, and communication reference

Target Frequency Source

Digital reference, analog signal reference, multi-segment speed reference, PI control reference, and communication reference

Control Signal Input Terminal

2 digital input

1 analog input ,support 0~10V4~20mA0~20mA signal

Control Signal Output Terminal

2 relay output

1 analog output ,support 0~10V4~20mA0~20mAsignal

 

Environment

Using Place

Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Altitude

0~4000mDerating use when more than 1000m (decrease by 1% per 100 meters)

Ambient Temperature

-10  to +40  (Derating use when under ambient temperature of 40  to 50 )

Humidity

Less than 95%RH, without condensing

Vibration

Less than 5.9m/s (0.6g)

Storge Temperature

20~60

Power Distribution System

TN, TT


AC Drives (VFD)

See All